Call 08046075509 84% Response Rate

our range

GYNECOLOGICAL TRAINING MANIKINS

We are a leading Manufacturer of leopold maneuvers simulator, prenatal cervix and birth canal model, child birth skill training simulator and delivery & maternal , neonatal emergency simulator from Coimbatore, India.
  • Leopold Maneuvers Simulator
  • Leopold Maneuvers Simulator
Leopold Maneuvers Simulator

Leopold Maneuvers Simulator

Rs 22,500  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Country of OriginMade in India
APPLICATIONTRAINING
FEATURESOG / COURSE OF DELIVERY
TYPEMANUAL
WARRANTY3 YEARS WARRANTY
CATALOG CODEKITE-F6 / PAGE 37
LEOPOLD MANEUVERS SIMULATOR / COURSE OF DELIVERY 

Features:

 

1. The automatic birthing system rotates baby as it moves through the birth canal.

2. The model shows seven stages of birh: engagement----descent----flexion-----internal rolling----spread-----reposition and external rolling----childbirthing.



Additional Information:

  • Delivery Time: IMMEDIATE
  • Packaging Details: WOODEN CARRYING CASE

View Complete details

get quote request a call back
  • Prenatal Cervix and Birth Canal Model
  • Prenatal Cervix and Birth Canal Model
  • Prenatal Cervix and Birth Canal Model
  • Prenatal Cervix and Birth Canal Model
Prenatal Cervix and Birth Canal Model

Prenatal Cervix and Birth Canal Model

Rs 15,000  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Country of OriginMade in India
APPLICATIONTRAINING
FEATURESOG / DELIVERY MODEL
WARRANTY3 YEARS WARRANTY
PACKINGCARRYING CASE
CATALOG CODEKITE-20G / PAGE NO :39

The simulators show the relationship between Prenatal Cervical Change and Birth Canal, facilitating the teaching, demonstration, and practice of cervical examination. 

 

Features:

 

1.  Six labor stations selected to represent conditions of the cervix and vagina prior to labor, during labor, and at birth.

 

2.  Stations illustrated are:

 

STA -5 prior to onset of labor; Stage 1 (no dilatation, no effacement)

STA -4 cervix partially effaced; Stage 2 (2 cm dilatation, 50% effacement)

STA -3 cervix fully effaced; Stage 3 (4 cm dilatation, full effacement)

STA  0  fetal head at plane of schial spine; Stage 4 (5 cm dilatation, full effacement)

STA +2 cervix nearing full dilation; Stage 5 (7 cm dilatation, full effacement)

STA +5 crowning of fetal head. Stage 6 (10 cm dilatation, full effacement)



Additional Information:

  • Delivery Time: IMMEDIATE
  • Packaging Details: CARRYING CASE

View Complete details

get quote request a call back
  • Child Birth Skill Training Simulator
  • Child Birth Skill Training Simulator
Child Birth Skill Training Simulator

Child Birth Skill Training Simulator

Rs 50,000  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

TypeTRAINING
Installation Service NeededNo
BrandKITE TECH
Country of OriginMade in India
CATALOG CODEKITE-F20 / PAGE 39
MATERIALPOLYMERISED RUBBER
CHILD BIRTH SKILL TRAINING SIMULATOR 

Features:

 

1. An anatomically correct pelvic model with fetus and placenta to give students experience with multiple technique and procedure for emergency childbirth.

2. Twinborn (one infant boy and one infant girl) presentation and delivery.



Additional Information:

  • Delivery Time: IMMEDIATE
  • Packaging Details: CARRYING CASE

View Complete details

get quote request a call back
  • Delivery & Maternal , Neonatal Emergency Simulator
  • Delivery & Maternal , Neonatal Emergency Simulator
  • Delivery & Maternal , Neonatal Emergency Simulator
Delivery & Maternal , Neonatal Emergency Simulator

Delivery & Maternal , Neonatal Emergency Simulator

Rs 3.5 Lakh  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Country of OriginMade in India
APPLICATIONTRAINING
FEATURESDELIVERY MANIKIN
WARRANTY3 YEAR WARRANTY
PACKINGTROLLEY WOODEN CASE
CATALOG CODEKITE-F55 / PAGE NO : 42
DELIVERY & MATERNAL , NEONATAL EMERGENCY SIMULATOR 

Features:

 

1. Prenatal nursing for pregnant women and fetal and postnatal nursing for mother & newborns
2. Life size, flexible joints, soft and removable abdominal wall
3. Tracheal intubation and simulate chest wavy state
4. Automatic birthing system, fully simulate the real delivery process,
5. Obstetric palpation examination.
6. Replaceable dilating cervices
7.Cervix examination model: Six simulation stages to represent conditions of cervix and the position relation between fetal head and plane of ischial spine;

Stations in the fist stage of labor:
1).Stage 1: no dilation of cervix, cervical canal does not efface, the position relation between fetal head and plane of ischial spine - 5,
2).Stage 2: dilation of 2cm of cervix, effacement of 50′ of cervical canal, position relation between fetal head and plane of ischial spine-4;
3).Stage 3: dilation of 4cm of cervix, full effacement of cervical canal, position relation  between fetal head and plane of ischial spine-3;
4).Stage 4: dilation of 5cm of cervix, full effacement of cervical canal, position relationship between fetal head and plane of ischial spine-0
5).Stage 5: dilation of 7cm of cervix, full effacement of cervical canal, position relation between fetal head and plane of ischial spine+2
6).Stage 6: dilation of 10 cm of cervix, full effacement of cervical canal, position relation  between fetal head and plane of ischial spine+5;
8. Check fetal head descent and cervix dilation
9. Simulate multiple placenta position
10. Venous channel for administration and nutrition in maternal arm
11. Exercise of postpartum cutting and suturing on perineum
12. Life size of normal newborns
13. Neonatal tracheal intubation
14. CPR of pregnant women: Take artificial respiration and external cardiac compression under the standards of 2005 international CPR guidelines, electronic monitoring of airway open, blowing volume, times and frequency, and compression times, frequency, position and depth;
15. Administration through umbilical vein;

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES